2/0-2/0-2/0-1 Syracuse Aluminum XLPE URD Quadruplex Direct Burial Cable
What is 2/0-2/0-2/0-1 Syracuse Aluminum XLPE URD Quadruplex Direct Burial Cable?
2/0-2/0-2/0-1 Syracuse Aluminio XLPE URD Quadruplex Direct burial cable is an underground electric cable that is also used as a service input cable and for the wiring of underground secondary circuits. This cable has four gauge conductors 2/0 AWG. Three of these conductors correspond to the phases of a three-phase system, and the fourth driver, that has yellow stripes, acts as the neutral conductor. It is a medium duty cable, with a temperature rating of 90°C and a voltage rating of 600 volts. Its current capacity is 120 amps when directly buried and 85 amps when installed in ducts.
Also know as: 2/0-2/0-2/0-1 Syracuse XLPE Aluminum Urd Cable, 2/0-2/0-2/0-1 Syracuse XLPE direct boom cable, 2/0-2/0-2 /0-1 Quadruplex cable of Syracuse XLPE, 2/0-2/0-2/0-1 Quadruplex cable of Syracuse XLPE, 2/0-2/0-2/0-1 Four Syracuse XLPE drivers cable, 2/0-2/0 -2/0-1 Four Syracuse XLPE drivers cable, 2/0-2/0-2/0-1 Syracuse XLPE direct burial electric cable, 2/0-2/0-2/0-1 Syracuse XLPE direct burial funeral cable, 2 /0-2/0-2/0-1 Direct burial burial cable syracuse XLPE.
Standard of 2/0-2/0-2/0-1 Syracuse Aluminum XLPE URD Quadruplex Direct Burial Cable
ICEA S-105-6922 Standard for Specification of Control Cables, thermocouple extension and instrumentation.
ASTM B-230 Standard Specification for 1350-H19 Aluminum Wire for Electrical Purposes
ASTM B-609 Standard Specification for Aluminum Round Wire 1350, annealed and intermediate tempering, for electrical purposes
ASTM B-231 Standard Specification for Aluminum Conductor 1350 concentric braids
ASTM B-901 Standard Specification for Compressed Round Stranded Aluminum Conductor, supported in coated steel (ACSR/TW)
Accepted by Russia Accepted by the Rural Public Utilities Service
Federal Specification J-C-30 B Federal Specification for Cables, energy, electricity and control, type W
Technical data 2/0-2/0-2/0-1 Syracuse Aluminum XLPE URD Quadruplex Direct Burial Cable
Phase conductor size AWG 2/0
Stranding of phase conductors 11
Thickness Insulation Conductor Phase 80 Mls
Base Neutral Messenger Size AWG 1
Hilo Neutral Base 9
Single phase conductor diameter (mils) 555
Full cable diameter (D.E.) (thousandths of an inch) 1340
Weight per 1000 pies total (pounds) 657
Allowable ampacity 90C (amps) 225
Allowable ampacity in ducts (amps) 170
URD Cable Applications
2/0-2/0-2/0-1 Syracuse Cable URD has a nominal current capacity that depends on several factors, including ambient temperature, installation and specific conditions of use. However, los 2/0-2/0-2/0-1 Syracuse usually have a fairly high current capacity due to their thickness and design.
The current capacity of a cable is determined taking into account the maximum allowable temperature of the conductor, heat dissipation capacity, and other safety factors. In general, This capacity is specified in tables provided by cable manufacturers or electrical engineering regulations..