2-2-2 Ramapo Aluminum XLPE URD triplex Direct Burial Cable

Triplex URD Cable

Contact Us

2-2-2 Ramapo Aluminum XLPE URD Triplex Direct Burial Cable

What is 2-2-2 Ramapo Aluminum XLPE URD Triplex Direct Burial Cable?

2-2-2 Ramapo Aluminum XLPE URD Triplex Direct Burial Cable It is intended for use in secondary distribution circuits, being suitable for installation in conduits or for direct burial applications. Maximum operating temperature should not exceed 90°C in wet and dry locations. The nominal voltage is 600 volts. As an option, This cable can be delivered pre-installed in conduit.

Also know as: ramapo aluminum urd cable 2-2-2 XLPE, ramapo urd direct burial cable 2-2-2 XLPE, ramapo three conductor cable 2-2-2 XLPE, cable triplex ramapo 2-2-2 XLPE, cable triplex, 2-2-2 Ramapo Triplex XLPE Aluminum Underground Cable, power cord 3 ramapo drivers 2-2-2 XLPE, aluminum triplex, ramapo underground triplex 2-2-2 XLPE, triplex ramapo underground cable 2-2-2 XLPE, cable triplex ramapo 2-2-2 underground XLPE, 2-2-2 triplex direct burial XLPE branch, 2-2-2 ramapo triplex conductor XLPE, 2-2-2 ramapo XLPE direct burial electrical cable, 2-2-2 ramapo direct burial XLPE power cable, 2-2-2 Aluminum Branch XLPE Direct Burial Cable.

Standard of 2-2-2 Ramapo Aluminum XLPE URD Triplex Direct Burial Cable

ICEA S-105-6922 Standard for Specification of Control Cables, thermocouple extension and instrumentation.
ASTM B-230 Standard Specification for 1350-H19 Aluminum Wire for Electrical Purposes
ASTM B-609 Standard Specification for Aluminum Round Wire 1350, annealed and intermediate tempering, for electrical purposes
ASTM B-231 Standard Specification for Aluminum Conductor 1350 concentric braids
ASTM B-901 Standard Specification for Compressed Round Stranded Aluminum Conductor, supported in coated steel (ACSR/TW)
Accepted by Russia Accepted by the Rural Public Utilities Service
Federal Specification J-C-30 B Federal Specification for Cables, energy, electricity and control, type W

Technical data 2-2-2 Ramapo Aluminum XLPE URD Triplex Direct Burial Cable

Phase conductor size AWG: 2
Wiring of phase conductors: 7
Phase conductor insulation thickness: 60 ml.
AWG Base Neutral Messenger Size: 2
base neutral hilum: 7
Single phase conductor diameter (mils): 403
Full cable diameter (O.D.) (mil): 870
Total weight per 1000 pies (pounds): 278
Allowable ampacity 90C (amps): 165
Allowable ampacity in ducts (amps): 120

URD Cable Applications

2AWG Ramapo Cable URD has a rated current capacity that depends on several factors, including ambient temperature, installation and specific conditions of use. However, los 2 AWG Ramapo typically have a fairly high current rating due to their thickness and design.

The current capacity of a cable is determined taking into account the maximum allowable temperature of the conductor, heat dissipation capacity, and other safety factors. In general, This capacity is specified in tables provided by cable manufacturers or electrical engineering regulations..

    Request a free quote, we will answer you in 24 hours.

    Your email*:

    Your name*:

    Your country:

    Your phone*:

    Your message*: