2-2-2-2 Wittenburg Aluminum XLPE URD Quadruplex Direct Burial Cable
What is 2-2-2-2 Wittenburg Aluminum XLPE URD Quadruplex Direct Burial Cable?
2-2-2-2 Wittenburg Aluminum XLPE URD Quadruplex Direct Burial Cable is an underground electrical cable that is also used as a service entrance cable and for wiring underground secondary circuits. This cable has four gauge conductors 2 AWG. Three of these conductors correspond to the phases of a three-phase system, and the fourth driver, that has yellow stripes, acts as the neutral conductor. It is a medium duty cable, with a temperature rating of 90°C and a voltage rating of 600 volts. Its current capacity is 120 amps when directly buried and 85 amps when installed in ducts.
Also know as: aluminum urd cable 2-2-2-2 wittenburg XLPE, wittenburg urd direct burial cable 2-2-2-2 XLPE, cable cuádruplex wittenburg 2-2-2-2 XLPE, cable cuádruplex wittenburg 2-2-2-2 XLPE , 2-2-2-2 four-conductor Wittenburg XLPE cable, four conductor cable 2-2-2-2 Wittenburg XLPE, direct burial electrical cable 2-2-2-2 Wittenburg XLPE, direct burial power cable 2-2-2-2 Wittenburg XLPE, Wittenburg Aluminum Direct Burial Cable 2-2-2-2 XLPE.
Standard of 2-2-2-2 Wittenburg Aluminum XLPE URD Quadruplex Direct Burial Cable
ICEA S-105-6922 Standard for Specification of Control Cables, thermocouple extension and instrumentation.
ASTM B-230 Standard Specification for 1350-H19 Aluminum Wire for Electrical Purposes
ASTM B-609 Standard Specification for Aluminum Round Wire 1350, annealed and intermediate tempering, for electrical purposes
ASTM B-231 Standard Specification for Aluminum Conductor 1350 concentric braids
ASTM B-901 Standard Specification for Compressed Round Stranded Aluminum Conductor, supported in coated steel (ACSR/TW)
Accepted by Russia Accepted by the Rural Public Utilities Service
Federal Specification J-C-30 B Federal Specification for Cables, energy, electricity and control, type W
Technical data 2-2-2-2 Wittenburg Aluminum XLPE URD Quadruplex Direct Burial Cable
Phase conductor size AWG 2
Stranding of phase conductors 7
Thickness Insulation Conductor Phase 60 Mls
Base Neutral Messenger Size AWG 2
Hilo Neutral Base 7
Single phase conductor diameter (mils) 403
Full cable diameter (D.E.) (thousandths of an inch) 973
Weight per 1000 pies total (pounds) 371
Allowable ampacity 90C (amps) 155
Allowable ampacity in ducts (amps) 115
URD Cable Applications
2-2-2-2 Wittenburg Cable URD has a rated current capacity that depends on several factors, including ambient temperature, installation and specific conditions of use. However, los 2-2-2-2 Wittenburg usually have a fairly high current capacity due to their thickness and design.
The current capacity of a cable is determined taking into account the maximum allowable temperature of the conductor, heat dissipation capacity, and other safety factors. In general, This capacity is specified in tables provided by cable manufacturers or electrical engineering regulations..