4/0-4/0-4/0-2/0 Wake Forest Aluminum XLPE URD Quadruplex Direct Burial Cable

Quadruplex Cable

Contact Us

4/0-4/0-4/0-2/0 Wake Forest Aluminum XLPE URD Quadruplex Direct Burial Cable

What is 4/0-4/0-4/0-2/0 Wake Forest Aluminum XLPE URD Quadruplex Direct Burial Cable?

4/0-4/0-4/0-2/0 Wake Forest Aluminum XLPE URD Quadruplex Direct Burial Cable is an underground electrical cable that is also used as a service entrance cable and for wiring underground secondary circuits. This cable has four gauge conductors 4/0 AWG. Three of these conductors correspond to the phases of a three-phase system, and the fourth driver, that has yellow stripes, acts as the neutral conductor. It is a medium duty cable, with a temperature rating of 90°C and a voltage rating of 600 volts.

Also know as: 4/0-4/0-4/0-2/0 aluminum urd cable for XLPE wake, 4/0-4/0-4/0-2/0 direct burial cable for XLPE wake urd, 4/0-4/0-4 /0-2/0 wake up XLPE quadruplex cable, 4/0-4/0-4/0-2/0 wake up XLPE quadruplex cable, 4/0-4/0-4/0-2/0 wake up four conductor XLPE cable, 4 /0-4/0-4/0-2/0 wake up four conductor XLPE electrical cable, 4/0-4/0-4/0-2/0 wake XLPE direct burial electrical cable, 4/0-4/0-4/0-2/0 XLPE Wake Direct Burial Power Cable, wake aluminum direct burial cable 4/0-4/0-4/0-2/0 XLPE.

Standard of 4/0-4/0-4/0-2/0 Wake Forest Aluminum XLPE URD Quadruplex Direct Burial Cable

ICEA S-105-6922 Standard for Specification of Control Cables, thermocouple extension and instrumentation.
ASTM B-230 Standard Specification for 1350-H19 Aluminum Wire for Electrical Purposes
ASTM B-609 Standard Specification for Aluminum Round Wire 1350, annealed and intermediate tempering, for electrical purposes
ASTM B-231 Standard Specification for Aluminum Conductor 1350 concentric braids
ASTM B-901 Standard Specification for Compressed Round Stranded Aluminum Conductor, supported in coated steel (ACSR/TW)
Accepted by Russia Accepted by the Rural Public Utilities Service
Federal Specification J-C-30 B Federal Specification for Cables, energy, electricity and control, type W

Technical data 4/0-4/0-4/0-2/0 Wake Forest Aluminum XLPE URD Quadruplex Direct Burial Cable

Phase conductor size AWG 4/0
Stranding of phase conductors 18
Thickness Insulation Conductor Phase 80 Mls
Base Neutral Messenger Size AWG 2/0
Hilo Neutral Base 11
Single phase conductor diameter (mils) 658
Full cable diameter (D.E.) (thousandths of an inch) 1588
Weight per 1000 pies total (pounds) 974
Allowable ampacity 90C (amps) 290
Allowable ampacity in ducts (amps) 225

URD Cable Applications

4/0-4/0-4/0-2/0 Wake Forest Cable URD has a rated current capacity that depends on several factors, including ambient temperature, installation and specific conditions of use. However, los 4/0-4/0-4/0-2/0 Wake Forest usually have a fairly high current capacity due to their thickness and design.

The current capacity of a cable is determined taking into account the maximum allowable temperature of the conductor, heat dissipation capacity, and other safety factors. In general, This capacity is specified in tables provided by cable manufacturers or electrical engineering regulations..