POWER CABLE (AS+) FIRE RESISTANT 0.6/1kV
What is power cable (AS+) fire resistant 0.6/1kV?
power cable (AS+) Fire resistant 0.6/1kV is a specialized type of electrical cable designed to operate safely and reliably under normal conditions, while providing exceptional fire resistance in the event of a fire. The classification “0,6/1 kV” indicates the tension capacity of the cable, suitable for systems with a nominal voltage of up to 1000 volts (con 600 volts as phase-to-phase voltage).

Power cable standard (AS+) fire resistant 0.6/1kV
IEC 60502-1 “Power cables with extruded insulation and their accessories for nominal voltages of 1 kV (One = 1,2 kV) until 30 kV (One = 36 kV) – Part 1: Cables for nominal voltages of 1 kV (One = 1,2 kV) y 3 kV (One = 3,6 kV)”
Norma IEC 60364-5-52, Table B.52.5, Method D1, Duct buried in the ground Ta: 20°C, Tc: 90°C.
NBR standard 5410, Tabla 39, Method F, Monopolar Cables flat layout (Horizontal o Vertical) outdoors, Facing: 30°C, Tc: 90°C, gauges 1.5 al 16 mm2.
Norma IEC 60364-5-52, Table B.52.12, Method F, Monopolar Cables flat layout (Horizontal o Vertical) outdoors, Facing: 30°C, Tc: 90°C.
Power cable features (AS+) fire resistant 0.6/1kV
Driver Material: Cobre recocido (cobre suave)
Flexibilidad del Conductor: Class 5
Forma del Conductor: Alambres trenzados
Isolation: XLPE (cross-linked polyethylene)
Libre de Halógenos: Yeah
Outer Cover: HFFR (libre de halógenos y retardante de llama)
Productos de cable de potencia (AS+) fire resistant 0.6/1kV
10 mm2
- Driver section: 10 mm²
- External diameter: 8,28 mm
- Approximate weight: 133,56 kg/km
- Nominal outside diameter: 8,28 mm
120 mm2
- Driver section: 120 mm²
- External diameter: 20,05 mm
- Approximate weight: 1159,88 kg/km
- Nominal outside diameter: 20,05 mm
16 mm2
- Driver section: 16 mm²
- External diameter: 9,17 mm
- Approximate weight: 189,4 kg/km
- Nominal outside diameter: 9,17 mm
2.5 mm2
- Driver section: 2,5 mm²
- External diameter: 6,16 mm
- Approximate weight: 53,86 kg/km
- Nominal outside diameter: 6,16 mm
25 mm2
- Driver section: 25 mm²
- External diameter: 10,84 mm
- Approximate weight: 278,83 kg/km
- Nominal outside diameter: 10,84 mm
35 mm2
- Driver section: 35 mm²
- External diameter: 12,01 mm
- Approximate weight: 372,12 kg/km
- Nominal outside diameter: 12,01 mm
4 mm2
- Driver section: 4 mm²
- External diameter: 6,71 mm
- Approximate weight: 70,69 kg/km
- Nominal outside diameter: 6,71 mm
50 mm2
- Driver section: 50 mm²
- External diameter: 13,71 mm
- Approximate weight: 513,76 kg/km
- Nominal outside diameter: 13,71 mm
6 mm2
- Driver section: 6 mm²
- External diameter: 7,29 mm
- Approximate weight: 90,96 kg/km
- Nominal outside diameter: 7,29 mm
70 mm2
- Driver section: 70 mm²
- External diameter: 15,68 mm
- Approximate weight: 705,87 kg/km
- Nominal outside diameter: 15,68 mm
Precio de venta de cable de potencia (AS+) fire resistant 0.6/1kV
The selling price of cable de potencia (AS+) fire resistant 0.6/1kV varies depending on a variety of factors. At the time of purchase, we indicate the price.
Fabricante de cable de potencia (AS+) fire resistant 0.6/1kV
Dosense Cable es fabricante de cable de potencia (AS+) resistentes al fuego 0.6/1kV, diseñados para garantizar la seguridad y confiabilidad en instalaciones críticas. Estos cables cumplen con estrictas normativas internacionales como IEC 60331 y IEC 60502-1, asegurando un rendimiento óptimo en condiciones extremas. Su construcción incluye aislamiento de materiales avanzados como XLPE y LSZH, que reducen la emisión de humo y gases tóxicos durante incendios.
Ideales para sistemas de emergencia, hospitals, centros de datos, transporte e infraestructura industrial, Dosense Cable's fire-resistant power cables offer maximum durability and electrical stability. Besides, The company specializes in customization to fit specific projects, Backed by innovative manufacturing processes and global certifications. Dosense Cable is synonymous with quality, security and reliability in advanced cabling solutions.