CABLE NYY UNIPOLAR BIPOLAR TRIPOLAR TETRAPOLAR

Cable NYY 1kV

Contact Us

CABLE NYY UNIPOLAR BIPOLAR TRIPOLAR TETRAPOLAR 0.6/1kV

What is CABLE NYY UNIPOLAR BIPOLAR TRIPOLAR TETRAPOLAR 0.6/1kV?

General application as power cable. In low voltage distribution networks, industrial facilities, in buildings and switchgear positions. In fixed installations, in indoor environments (on trays, canales, stapled, etc.); outdoors, in underground or directly buried conduits. Can be installed in dry and humid locations.

A, of the, three or four annealed copper conductors, solids, braided (pills, compacted or sectorial) or flexible. PVC insulation, with or without ground conductor (isolated) and PVC outer cover.

Characteristics Good electrical and mechanical properties. PVC outer jacket provides adequate acid resistance, fats, oils and abrasion. Facilitates splicing, derivations and endings. Flame retardant.

Tagged INDECO S.A. NYY (80°) 0,6/1 kV <Section> <Year> <Sequential measurement>

Norma(s) manufacturing NTP-IEC 60502-1

Calibers 6 mm² – 500 mm²

Packing in wooden coils, in required lengths.

Insulation colors (¹): Blanco, Negro, Rojo, Azul, Yellow. External cover: Negra.

NYY UNIPOLAR TECHNICAL DATA TABLE

SECTION

NUMBER OF WIRE

THICKNESSES

EXPECTED DIAMETER

EXPECTED WEIGHT

CURRENT CAPACITY (*)

ISOLATION

DECK

BURIED

AIRE

DUCT

N° x mm²

mm

mm

mm

(Kg/Km)

A

A

A

1 x 6

7

1

1.4

7.9

112

72

54

58

1 x 10

1

1

1.4

8.5

150

95

74

77

1 x 16

7

1

1.4

9.7

222

127

100

102

1 x 25

7

1.2

1.4

11.3

330

163

131

132

1 x 35

7

1.2

1.4

12.3

431

195

161

157

1 x 50

19

1.4

1.4

13.9

568

230

196

186

1 x 70

19

1.4

1.4

15.6

778

282

250

222

1 x 95

19

1.6

1.5

18.1

1068

336

306

265

1 x 120

37

1.6

1.6

19.8

1323

382

356

301

1 x 150

37

1.8

1.6

21.6

1610

428

408

338

1 x 185

37

2

1.7

23.9

2007

483

470

367

1 x 240

37

2.2

1.8

26.9

2606

561

565

426

1 x 300

37

2.4

1.9

29.7

3243

636

646

480

1 x 400

61

2.6

2

33.1

4110

730

790

555

1 x 500

61

2.8

2.1

36.7

5118

823

895

567

NYY BIPOLAR TECHNICAL DATA TABLE

SECTION

NUMBER OF WIRE

THICKNESSES

EXPECTED DIAMETER

EXPECTED WEIGHT

CURRENT CAPACITY (*)

ISOLATION

DECK

BURIED

AIRE

DUCT

N° x mm²

mm

mm

mm

(Kg/Km)

A

A

A

2 x 6

1

1

1.8

15.9

378

68

48

56

2 x 10

1

1

1.8

17.5

500

90

66

75

2 x 16

7

1

1.8

18.7

650

116

89

95

2 x 25

7

1.2

1.8

22

945

145

118

120

2 x 35

7

1.2

1.8

24

1210

175

145

145

NYY THREE-POLAR TECHNICAL DATA TABLE

SECTION

NUMBER OF WIRE

THICKNESSES

EXPECTED DIAMETER

EXPECTED WEIGHT

CURRENT CAPACITY (*)

ISOLATION

DECK

BURIED

AIRE

DUCT

N° x mm²

mm

mm

mm

(Kg/Km)

A

A

A

3 x 6

7

1

1.8

16.2

428

56

41

45

3 x 10

7

1

1.8

17.7

587

75

57

60

3 x 16

7

1

1.8

19.8

815

99

76

80

3 x 25

7

1.2

1.8

23.3

1201

128

101

103

NYY TETRAPOLAR TECHNICAL DATA TABLE

SECTION

NUMBER OF WIRE

THICKNESSES

EXPECTED DIAMETER

EXPECTED WEIGHT

CURRENT CAPACITY (*)

ISOLATION

DECK

BURIED

AIRE

DUCT

N° x mm²

mm

mm

mm

(Kg/Km)

A

A

A

4 x 16

7

1

1.8

21.5

1009

99

76

80

4 x 25

7

1.2

1.8

25.8

1522

128

101

103

4 x 35

7

1.2

1.8

28.4

1979

155

125

125

4 x 50

19

1.4

2

32.7

2637

184

151

149

4 x 70

19

1.4

2.1

36.8

3563

226

192

180

4 x 95

19

1.6

2.2

42.6

4863

272

232

217

4 x 120

37

1.6

1.8

45.3

5835

310

269

248

3×25/16

7

1.2

1.8

24.6

1381

128

101

103

3×35/16

7

1.2

1.8

27

1750

155

125

125

3×50/25

19

1.4

1.9

31.1

2361

184

151

149

3×70/35

19

1.4

2.1

35.2

3215

226

192

180

3×95/50

19

1.6

2.2

40.5

4324

272

232

217

3×120/70

37

1.6

2.4

44.5

5410

310

269

248

3×150/70

37

1.8

2.5

48.6

6452

348

309

278

3×185/95

37

2

2

52.8

7933

394

353

311

3×240/120

37

2.2

2.9

60.6

10451

458

415

361

Technical data of CABLE NYY UNIPOLAR BIPOLAR TRIPOLAR TETRAPOLAR 0.6/1kV

NYY cables are a type of power and control cable commonly used in fixed installations. They have copper conductors with insulation and PVC coating, making them suitable for indoor and outdoor applications, including underground and underwater facilities. The standard voltage rating of NYY cables is 0,6/1 kV.

The terms “unipolar”, “bipolar”, “tripolar” y “tetrapolar” refer to the number of conductors within the cable:

Unipolar: A single driver
Bipolar: two drivers
Tripolar: three drivers
Tetrapolar: four conductors
These configurations allow NYY cables to adapt to various electrical requirements, providing flexibility in power distribution and control applications.

When selecting a NYY cable, It is important to take into account factors such as the installation environment, specific mechanical protection needs and electrical parameters to ensure optimal performance and compliance with relevant standards.

CABLE Manufacturer NYY UNIPOLAR BIPOLAR TRIPOLAR TETRAPOLAR 0.6/1kV

NYY unipolar cable, bipolar, Three-pole and four-pole 0.6/1kV is widely used in fixed electrical installations for power distribution.. This type of cable is manufactured by various companies specialized in electrical conductors.. A prominent manufacturer of these cables is Dosense Cable, which specializes in the production of low and medium voltage cables.

NYY cables are designed with copper conductors, PVC insulation and cover, which gives them excellent weather resistance, humidity and underground environments. Its versatility allows it to be used both indoors and outdoors., including industrial and commercial environments.

Unipolar variants, bipolar, Tripolar and tetrapolar refer to the number of conductors they contain., allowing them to adapt to different electrical needs, from single-phase to three-phase power systems. Dosense Cable offers these cables with high quality, complying with international regulations and ensuring reliable performance in all types of installations.

    Request a free quote, we will answer you in 24 hours.

    Your email*:

    Your name*:

    Your country:

    Your phone*:

    Your message*: